White Horse Laboratories: Week 40 Quality Report

White Horse Laboratories: Week 40 Quality ReportIn Week 40, White Horse facilitated USD201,367.00 in successful transactions!

Electrical Testing – 55% Pass

Physical Inspection – 71% Accept

Week 40 saw failures in a variety of device categories, rather than the predominantly discrete (passive and active) that we had been seeing in previous weeks.

Be on the lookout for the following high risk devices*:

Atmel AT45DB161D-TU, 27% failure – erase, program, and verify errors.

Atmel ATMEGA1281V-8MU, 36% failure – ID and blank check errors.

ON Semiconductor NTB60N06T4G, 100% failure – low power handling capability.

STMicroelectronics VNH3ASP30-E, 9% failure – wrong output state and high supply current at no load.

Maxim MAX6192AESA+, 40% failure - high and low output voltages (mixed bag).

Analog Devices AD1139J, 17% failure - static output voltage when writing any data.

Infineon BTS3142D, 6% failure – mixed parametric failures (mixed bag).

* Note: high risk is defined as devices with over a 5% failure rate in electrical testing.

Quality drives a company’s reputation, its bottom line and above all, its value.



Comments are closed

The Contributor

Have Your Say!

Which part of Shenzhen has the best quality of life for foreigners?

View Results

Loading ... Loading ...

  1. Etienne Ducrot: Hi, I’m interested to contact this Foundation. Do you know how? Thanks. Etienne
  2. Emma: Hi Jasmin, I’ve read your article about a new medical center opens in Nanshan at the end of this month....
  3. sherry lee: A simple story with great words…I love it.
  4. Evangeline: Awesome piece!
  5. Glenda: Hi there, I enjoy reading through your article post. I wanted to write a little comment to support you.