White Horse Laboratories Counterfeit Detection Report Week 29

White Horse Laboratories Counterfeit Detection Report Week 29The barage of reports is nearly over. With this Week 29 report, we are back on schedule and will resume our regular weekly schedule.

There was a reversal in electrical testing with only batch having a failure rate higher than 5%, climbing to nearly an 89% pass rate in Week 29 for all lots tested, jumping up from 55%. Inspection results edged lower to 55% from 58% in Week 28. Physical inspection effectively eliminated many suspect devices before testing was required.

With one week remaining in the July poll, the number of respondents who believe sales are being impacted by heightened buyer scrutiny is is up to 89%. Cast your vote!

Post your vote and view results on July’s poll at http://conta.cc/MlepTE.

Inspection: 54.5% Accept    Testing: 88.9% Pass

Week 29 Quality Report, 2012  Substandard Part Listing

Xilinx XC5VLX85T-1FFG1136I (Date Code 1141) – 7.93% failure – Program error from Vcc pins short to ground.

As parts had been re-balled, the shorts would have come from the re-balling processes.